An electrical grid's final step-down in voltage occurs through a Distribution Transformer. This critical component takes the higher primary voltage from distribution lines and transforms it to the lower, usable voltage levels required by homes, commercial buildings, and industrial facilities. Reliable and efficient distribution transformers are foundational to a stable power supply. Our range includes specialized types like the On Load Regulator Transformer, which maintains consistent output voltage despite fluctuating load conditions, and the versatile Pole Mounted Transformer, a space-saving solution for overhead distribution networks. For applications demanding high durability and efficient cooling, our robust Oil Immersed Transformer is engineered for longevity. While a Distribution Transformer handles the final voltage delivery, a larger Power Transformer is typically used in transmission substations for bulk power transfer at much higher voltages.
The DTR-500 Series Distribution Transformer exemplifies our commitment to engineering excellence for modern power networks. Designed for optimal performance in diverse environments, this transformer series prioritizes energy efficiency, mechanical strength, and operational safety. Below are the key technical parameters that define the DTR-500 Series. For specific models, please refer to the detailed specification tables.
| Parameter | Specification Range | Remarks / Standard |
|---|---|---|
| Rated Power (kVA) | 50, 100, 200, 315, 500 | Custom ratings available upon request. |
| Primary Voltage (kV) | 11, 22, 33 | As per regional distribution standards. |
| Secondary Voltage (V) | 433/250 (3-phase) / 240/120 (1-phase) | Standard LV supply voltages. |
| Vector Group | Dyn11, Yyn0 | Common configurations for neutral stability. |
| No-Load Loss (Po) | As per IEEE C57.12.00 / IEC 60076 | Optimized for energy efficiency levels (e.g., EI2, EI3). |
| Load Loss (Pk) | As per IEEE C57.12.00 / IEC 60076 | Measured at reference temperature. |
| Impedance Voltage (%) | 4.0 - 6.0 | Typical range for fault current limitation. |
| Sound Level (dB(A)) | < 55 (at 1m for 500kVA) | Designed for low-noise residential areas. |
| Insulation Level (HV/LV, kV) | 28/3.6 (for 11kV system) | Basic Impulse Level (BIL) as per system voltage. |
| Operating Temperature | -25°C to +45°C | Ambient temperature range. |
| Altitude | Up to 1000m ASL | Standard rating; derating applies above. |
| Protection Degree (IP Code) | IP54 (outdoor) | Protection against dust and water ingress. |
| Standards Compliance | IEEE C57.12.xx, IEC 60076, ANSI, CSA | Manufactured to international standards. |